Withdraw excess fluid to alleviate overfill, or, with the Quick Fill method, make sure the IV bag is not hanging any higher than 12 inches (30 cm) above the training model

    • Removing Air

      To remove air:

      1. Fill a syringe with fluid and connect it to the tube.

      2. Infuse fluid, and tilt the model up at least 6-10” so any air rises to the top.

      3. Let the model sit for at least one hour to allow any air to rise.

      4. Use the syringe to slowly pull the fluid out of the model.

      5. Watch for air bubbles and let them rise to the top (back) of the syringe.

      6. Slowly push fluid back in without pushing the air in.

      7. Repeat steps 4-6 three to four times.

      8. Empty the syringe into a container and use it to remove any additional fluid, then disconnect it.



    • NOTE: When all the fluid is removed, the syringe will be under vacuum. Do not put excessive

      force on the syringe or the tissue may rupture.

      9. If there is still air, fill any fluid spaces or vessels with fluid and let the model sit overnight, then

      repeat the procedure.